Visient's mission is to alleviate our clients of the complexities
and time consuming tasks required to set-up, maintain, and
support their internet technology infrastructure. From running
a single portal to hosting an enterprise application servicing
thousands of individual agent sites, we have the experience
and resources to meet and exceed our customers needs. Our
cost-effective Tier-One-Facility hosting encompasses the
following:
Internet Connectivity
Visient offers a hosting network engineered to provide redundancy
throughout the data center, including dual Ethernet connections
running
across a completely fault-tolerant infrastructure
from core routers and ring-protected Packet Over Sonet (POS)
fiber network, to multiple, geographically diverse peering
points.
100% Uptime Guarantee on Internet Access
Transit Peering Agreements with Multiple Tier 1 Providers
Power
Our hosting facility incorporates a steady stream of power from the local
utility company and back-up power using a state of the art constant power supply
(CPS)
and diesel generators. With CPS, there is no need for battery operated uninterruptible
power supply (UPS) units. Instead, short term backup power supply is completely
generated
from flywheel systems and then power is sustained using diesel generators for
long-term backup power. On-site fuel supplies ensure power availability
for days at a time. Contracts with local fuel suppliers allow for power indefinitely.
Security
Visient's hosting facility utilizes layered security to safeguard
the data center 24 hours a day, 7 days a week, 365 days a year.
Comprehensive
physical
site security includes:
A single point of entry into the facility for employees and clients
Coded key cards for entry into the data center
Biometric scanners
Surveillance cameras located throughout the facility
Database of individuals authorized to access the facility
Manned security force
Whether managing physical site security or the security of client data,
the security model is based on authentication, authorization, and accountability.
Environmental Controls
HVAC Systems
5 chillers at 1,250 tons (n+1), electrical centrifugal system
(2) 18-inch pipes to assist cooling (below floor)
500,000 gallons of water stored on site
Constant 68-72°F
2 water towers at 250,000 gallons each
218 humidity control devices
Fire Suppression
VESDA detection system
10 miles of piping for air sampling
300 alarm points above and below data center floors
Chemical fire suppression system
Halatron fire extinguishers
Zoned, pressurized air and water release
Protect your investment