Visient's mission is to alleviate our clients of the complexities and time consuming tasks required to set-up, maintain, and support their internet technology infrastructure. From running a single portal to hosting an enterprise application servicing thousands of individual agent sites, we have the experience and resources to meet and exceed our customers needs. Our cost-effective Tier-One-Facility hosting encompasses the following:
Internet Connectivity
Visient offers a hosting network engineered to provide redundancy throughout the data center, including dual Ethernet connections running across a completely fault-tolerant infrastructure from core routers and ring-protected Packet Over Sonet (POS) fiber network, to multiple, geographically diverse peering points.
  • 100% Uptime Guarantee on Internet Access
  • Transit Peering Agreements with Multiple Tier 1 Providers
  • Power
Our hosting facility incorporates a steady stream of power from the local utility company and back-up power using a state of the art constant power supply (CPS) and diesel generators. With CPS, there is no need for battery operated uninterruptible power supply (UPS) units. Instead, short term backup power supply is completely generated from flywheel systems and then power is sustained using diesel generators for long-term backup power. On-site fuel supplies ensure power availability for days at a time. Contracts with local fuel suppliers allow for power indefinitely.
Security
Visient's hosting facility utilizes layered security to safeguard the data center 24 hours a day, 7 days a week, 365 days a year. Comprehensive physical site security includes:
  • A single point of entry into the facility for employees and clients
  • Coded key cards for entry into the data center
  • Biometric scanners
  • Surveillance cameras located throughout the facility
  • Database of individuals authorized to access the facility
  • Manned security force
Whether managing physical site security or the security of client data, the security model is based on authentication, authorization, and accountability.
Environmental Controls
  • HVAC Systems
    • 5 chillers at 1,250 tons (n+1), electrical centrifugal system
    • (2) 18-inch pipes to assist cooling (below floor)
    • 500,000 gallons of water stored on site
    • Constant 68-72°F
    • 2 water towers at 250,000 gallons each
    • 218 humidity control devices
  • Fire Suppression
    • VESDA detection system
    • 10 miles of piping for air sampling
    • 300 alarm points above and below data center floors
    • Chemical fire suppression system
    • Halatron fire extinguishers
    • Zoned, pressurized air and water release